					Voir ® Hydrogen stack humidity control sheet N-INF 
 | 
	
Scheme Description 
	 The wet heat test results of fuel cell stacks before leaving the factory show that no matter how well sealed the fuel cell stack is, condensation cannot be avoided. Condensation causes the following hazards: The wet heat test results of fuel cell stacks before leaving the factory show that no matter how well sealed the fuel cell stack is, condensation cannot be avoided. Condensation causes the following hazards:
1. It is easy to cause a short circuit of components, resulting in explosion and other hazards.
2. Long term operation of electronic components in high humidity environments can shorten their service life.
3. It is easy to cause adverse phenomena such as rust and mold on parts.
Voir ® N-INF flame-retardant intelligent humidity control sheet utilizes the high humidity environment moisture absorption and low humidity environment moisture release characteristics of polymer absorbent resin to efficiently regulate the internal humidity of the stack. Prevent the humidity inside the fuel cell package from rising to the dew point and suppress condensation. It has a flame retardant effect, avoiding short circuit faults and disasters, and reducing service costs.
1. Excellent moisture absorption, with moisture control and moisture-proof function
2. Squeezing without deformation and without water leakage
3. Flame retardant grade V0, in compliance with hydrogen industry standards
4. High moisture absorption rate, about 7 times that of ordinary desiccants
5. Controllable reverse humidity, also applicable below 0 ℃
6. No need for electricity, can be used directly, with a service life of 8 years
7. Customizable and recyclable
	
	
Product selection
	 
 
	
Product Selection
Contact Us
Phone: 13927334215
Email: R0@voir-tech.com.cn
Address: 2nd Floor, Building D, Lingyun Science and Technology Park, No. 13 Jinda Road, Huinan High tech Industrial Park, Huicheng District, Huizhou City, Guangdong Province


 
  
 
   
 
 Voir® ePTFE humidification membrane core
Voir® ePTFE humidification membrane core Voir ® hollow fiber membrane
Voir ® hollow fiber membrane Voir ® moisture control materials
Voir ® moisture control materials Voir®H2 Folding membrane humidifier
Voir®H2 Folding membrane humidifier Voir®H2 Hydrogen humidifier
Voir®H2 Hydrogen humidifier Voir®H2 Humidifier (80-120KW for light trucks)
Voir®H2 Humidifier (80-120KW for light trucks) Voir®H2 Humidifier (10-30KW for forklifts)
Voir®H2 Humidifier (10-30KW for forklifts) Voir®H2 Humidifier (150-240KW for heavy-duty trucks)
Voir®H2 Humidifier (150-240KW for heavy-duty trucks) PEM enhanced membrane
PEM enhanced membrane Voir®H2 coolant particle filter
Voir®H2 coolant particle filter Voir®H2 anode water separator
Voir®H2 anode water separator Voir®H2 cathode water separator
Voir®H2 cathode water separator Voir®oil related transmission system protection
Voir®oil related transmission system protection Voir®breathable valve and oil proof  valve
Voir®breathable valve and oil proof  valve Voir®expansion drain valve
Voir®expansion drain valve Voir®bidirectional pressure relief valve
Voir®bidirectional pressure relief valve Voir®hydrogen fuel cell stack humidity control sheet
Voir®hydrogen fuel cell stack humidity control sheet Voir®intelligent humidity controller
Voir®intelligent humidity controller Voir®VHD100 Deionizer
Voir®VHD100 Deionizer Voir®VH220kw Deionizer
Voir®VH220kw Deionizer Voir®冷却液颗粒过滤器
Voir®冷却液颗粒过滤器 WeChat
WeChat Mobile Site
Mobile Site